If other displays do not appear, refer to manual. Adjust hours with and buttons, AM/PM toggles at 12 3. Is There Enough (Or Too Much) Water in the Tank? The dealer should read this page and guide the installer regarding hardness, day override, and time of regeneration, before installation: For the installer, the following must be used: · Set Installer Settings... Hardness, Day Override (preset to 12 days), and Time of Regeneration (preset to 2:00 a. m. ) · Read Normal Operating Displays · Set Time of Day · Read Power Loss & Error Display For the homeowner, please read operating instructions and displays. Adjust hardness using t and s buttons 3. Reverse Osmosis Systems. NOTE: At no time should there be "large particles" of media noticed at faucet or laundry tub. Here you will find the resources necessary to perform all manner of technical support for your US Water softener. Water Softener Troubleshooting - Identify and Fix. WS Series Control Value Owners Manual. DRAIN LINE: First, be sure that the drain can handle the backwash rate of the system. A single-tank softener should be set to regenerate at night.
  1. Water tec water softener manual
  2. Water technologies water softener manual.html
  3. Water softener service manual

Water Tec Water Softener Manual

Check to see if the breaker has been thrown. The system will begin to regenerate immediately. Again, check drain that it can receive the flow of water. Do not elevate overflow line higher than 3" below bottom of overflow fitting. Greenway Water Conditioners are precision built, high quality products. The system runs through the steps automatically and will reset itself to provide treated water when the regeneration has been completed. When troubleshooting a malfunctioning softener, you may want to run each regeneration step manually. When Manually Regenerating a Water Softener, How Long for Each Cycle? A negative pressure in the building combined with the softener being in regeneration could cause a siphoning of brine into the building. NOTE: The system regeneration sequence for softeners is in one of the two following sequences. The control valve may be stepped through the various regeneration cycles by pressing the regen button. CAUTION: If water flows too rapidly, it could result in loss of media to the drain. When Manually Regenerating a Water Softener, How Long for Each Cycle. Transformer was unplugged from either wall outlet or form PC board. Brine (Regenerant) Post Fill Backwash Brine (Regenerant) Pre Fill Fill Regenerate (Brine) Softening Second Backwash* Backwash Rinse Regenerate (Brine) Fill Second Backwash Service Rinse * Optional Service The system is now ready for filling with water.

Then the softener flushes the salt brine out of the treatment medium and down the drain so the cleaned treatment medium will be ready to treat more water. 25 Drawings & Service Manual 1" Control Valve Series Model: WS1 1. 1* Refill port plug assembly 1 2 Elbow locking clip 1 3 Tube insert, 3/8 1 4 Nut, 3/8 1 5 Elbow cap, 3/8 1 6 O-ring 019 1 7 ** Refill flow control retainer assy. When stepping through any displays or programming, if no buttons are pressed within 5-minutes, the display returns to a normal user display. If it comes on during the day when water usage is higher, you may get hard water because the unit can't keep up with you. When that happens, it's time for a new water softener. 5 amperes · the plug-in transformer is for dry locations only WELL WATER INSTALLATION MUNICIPAL INSTALLATION Air Gap To Drain Air Gap To Drain Waste connections or drain outlets shall be designed and constructed to provide for connection to the sanitary waste system through an air gap of 2 pipe diameters or 25 mm (1 in), whichever is larger. Water tec water softener manual. 3 The pH listed is the minimum for the influent water. This manual is about a control valve to be used on water softeners or water filters. If the building's electrical system is grounded to the plumbing, install a copper grounding strap from the inlet to the outlet pipe.

Water Technologies Water Softener Manual.Html

Water must flow into the brine/salt tank and then back out for the water softener to do its job. Plumbing must be done in accordance with all applicable local codes. If water is available on the outlet side of the softener or filter, it is an indication of water bypassing the system (Fig. ADVANCE CABINET SERIES WATER SOFTENER MANUAL. If water is not entering the tank, perhaps the float switch is stuck or there is a clog in its tubing. NOTE: Hardness display shows "-nA-" if used as a filter. Check the brine line for suction (after unit is full).

Replace drive cap assy. STEP 3 Day Override: When gallon capacity is set to off, sets the number of days between regenerations. 1 Injector cap 1 2 O-ring 135 1 3 Injector screen 1 4 Injector assembly plug 1 E injector assembly, white 5 F injector assembly, blue not shown O-ring 011, lower * not shown O-ring 013, lower * * The injector plug and the injector each use one lower and one upper o-ring REFILL PORT ASSEMBLY Item No. Install a 1/2" I. D. flexible plastic tube to the Drain Line Assembly or discard the tubing nut and use the 3/4" NPT fitting for rigid pipe (recommended). Water softener service manual. For units that "Post Fill, " the unit is now in the FILL position. Making internal changes to the system's operation will affect how it operates and may affect its functionality.

Water Softener Service Manual

During the regeneration cycle this position provides regeneration water to the unit, while also providing untreated water to the distribution system (Fig. Description 1 474 safety elbow 3/8" 2 474. Consult dealer for proper cleaning instructions. To access this mode, press set clock. If the dry salt storage feature is not being utilized, block salt may be used. Water technologies water softener manual.html. Please study this manual carefully and understand the cautions and notes before installing.

Verify that water is being drawn from regenerant tank with no air leaks or bubbles in the brine line. INLET/OUTLET PLUMBING: Be sure to install Bypass Valve onto main control valve before beginning plumbing. If it is desired to change this sequence, please refer to the Dealer Manual or contact the manufacturer. ) 1 Locking clip, elbow 1 2 Insert, 5/8" tube OP 3 Nut, 3/4" drain elbow OP 4 Drain elbow assembly, 3/4" NPT 1 5 O-ring 019 1 6 DLFC retainer assembly 1 0. Guelph, Ontario, Canada ·Phone:1-888-5-WATER-0 ·Fax:519-837-8913 Preinstallation Instructions: The manufacturer has set the water treatment unit's sequence of cycles, cycle times, salt dose, exchange capacity, and gallon capacity. Install an inlet shutoff valve and plumb to the unit's bypass valve inlet located at the right rear as you face the unit. 3/4" NPT Proper DLFC orientation directs water flow towards the washer face with rounded edge and lettering. There should be a rapid flow to the drain. Normal Operation Position: The inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the control valve. Model Brine Refill Backwash Brine & Rinse Rapid Rinse Total GACS835 Min. Valve does not regenerate automatically when regen button is depressed A. defective PC board CORRECTION A. replace motors B. repair outlet or use working outlet C. replace PCboard E. replace gear or drive cap assy. Bypass Position: The inlet and outlet handles point to the center of the bypass. 2 on page 2) and the control valve in normal operation where the display shows either the time of day or the gallons remaining: Manually add 3 GALLONS of water to the regenerant tank. Water will flow steadily at the drain.

Days remaining is an optional display but is not normally used. For units that "Pre Fill" the brine tank, the valve will cycle back to the normal operating position. 2 Iron removal may vary depending on form of iron, pH and other local conditions. Press next to go to step 5. The handles identify the direction of flow.